PROBLEM
Deep pitting corrosion in the bottom third (liquid zone) of separator vessel shell, circumferential welds, drain nozzles and manholes caused by an acidic process feed combined with high operating temperatures
SOLUTION
IGS HVTS technology chosen to upgrade the internal metallurgy of the vessel surface, avoiding costly and time-consuming replacement.
OUTCOME
Inspection in January 2023 confirmed HVTS cladding to be in perfect condition with no new corrosion or metal loss.
Separator Vessel
Leading exploration and production upstream company with around 209 producing oil&gas wells (onshore and offshore), was experiencing deep pitting (up to 8mm) in the bottom shell area between 4 to 8 O’clock position, the bottom third of the circumferential welds, bottom drain nozzles and manholes. The corrosion is caused by an acidic process feed (hydrocarbon gas/liquid & water) and the high operating temperatures.
Without addressing the corrosion mechanism, the vessel containment would be lost and replacement required.
High Velocity Thermal Spray Technology
IGS High Velocity Thermal Spray technology was selected to upgrade the carbon steel internal surface metallurgy of the vessel in-situ, with a high nobility alloy, arresting further metal degradation from the corrosive environment and substantially extending the asset service life, thereby avoiding costly and time-consuming replacement of the vessel.
HVTS Application
Surface grinding was conducted to remove sharp edges and open up deeply pitted areas to comply with the surface acceptance criteria for HVTS application.
IGS applied HVTS to clad of a total of 157 M² of the Flow Splitter Vessel internal surface + 17 Nozzles:
Covid-19
IGS provide a turnkey solution, installing in-situ a metallurgical upgrade to vessel/column internal shell areas and nozzles. IGS operational capabilities were proven by executing the project during the height of the COVID-19 pandemic in September 2020, delivering IGS high performance HVTS cladding ahead of schedule. IGS quality control standards were in full compliance with the Client’s specification for High Velocity Thermal Spray Coating.
Key Dates
Inspection
The asset owner’s maintenance team and IGS inspected the V6701 Flow Splitter in January 2023. They found that the H2S corrosion mechanism had been permanently mitigated with the application of IGS proprietary HVTS technology.
For the asset owner, this inspection was a crucial milestone in the validation process of the HVTS technology, and, as a result, they will now adopt IGS HVTS to permanently stop metal degradation in high-temperature acidic environments throughout the company’s field equipment.
IGS EXPERIENCE
IGS HVTS cladding technology is installed in-situ to protect the internal surfaces (shell and nozzles) of mission critical equipment against aggressive corrosion or erosion, thereby substantially reducing the total life cycle costs of equipment operation at upstream and downstreamoil and gas facilities in the Middle East and throughout the world.
Related Case Studies:
Column Shell Corrosion Protection Verified
Gas Turbine Corrosion Mitigated by HVTS and Hex Chrome Filtration System
HVTS Prevents Corrosion Attack in a Regenerator Column at LNG Plant
Severe Amine Column Corrosion Permanently Frozen
HVTS Stops Sour Water Stripper Corrosion
Caustic Vessel Protected After Repeated Failure
CATEGORIES:
IGS is here to provide information, answer questions and create an effective solution for your needs.
IGS is here to provide information, answer questions and create an effective solution for your needs.