Maintenance-Free Specification Addresses Severe CFB Boiler Erosion

Boiler Units and Wastage Mechanisms

This Fertilizer Plant in Pakistan is operating a Cogeneration Plant to supply steam to their parent business. Boiler reliability is imperative to them.
Two CFB boilers went into operation. A year after being in service, a big erosion problem was discovered, necessitating a long-term solution.

PROBLEM

A significant erosion problem was identified in a relatively new boiler that was only in operation for one year.

SOLUTION

IGS SMARTGard® was invited to remedy the problem and created a 3-year maintenance-free customized specification for this plant. IGS evaluated wear rates in each location and developed a bespoke specification as a result. As requested, the plant can now undertake a major project once every three years, rather than perform intermittent refurbishment.

CFB-boiler

Free consultation with an IGS Subject Matter Expert

IGS is here to provide information, answer questions and create an effective solution for your needs.