Proven HVTS® Performance After Seven Years in Service

Valero Port Arthur implemented HVTS® cladding on a KO Drum in 2019 as a long-term alternative to recurring internal Belzona applications and welding repairs.

Seven years later, inspection confirms the system remains fully intact, eliminating the need for repeat repairs and validating a lower total cost of ownership.

T19-5276

Traditional Options vs HVTS® Cladding

Approach Lifecycle Impact Operational Burden
Weld Overlay High upfront cost + complex execution Heat input, distortion, extended schedule
Organic Coatings Requires reapplication Repeated outages and maintenance
Section Replacement High total installed cost Cutting, rigging, welding, NDE, downtime, schedule uncertainty
HVTS® Cladding One-time application No repeat intervention required

HVTS® was ultimately selected to eliminate repeat maintenance and reduce the total cost of ownership through a single turnkey solution.

This performance is driven by a dense, low-permeability alloy structure with high bond strength, designed to inhibit corrosive pathways and protect the substrate long term.

Turnkey Execution with High Alloy Protection

2019 Scope Of Work Summary

Scope Details
Asset KO Drum (Hydrocracker Unit)
Area 717 ft² internal surface
Material IGS NiCrMo HVTS cladding
Thickness ~20 mil nominal
Duration 12 shifts (144 hours)
Execution Full turnkey delivery

The solution upgraded the vessel with a modified Hastelloy C-276 corrosion-resistant alloy barrier, eliminating future internal repair scope while avoiding heat input and simplifying turnaround execution.

Seven Years Of Proven Performance without Degradation

A 2026 inspection confirmed that the HVTS cladding remains in its original as-applied condition, with no degradation, metal loss, or reapplication required, confirming true long-term protection.

Proven Performance Builds Confidence Across the Site

This was the first IGS application at Valero Port Arthur and the first to be reinspected, setting a benchmark for long-term reliability within the refinery.

This project was about giving the site certainty. Not just solving corrosion in the short-term, but removing it from the refinery’s future maintenance scope. Seven years later, the vessel is still protected, and that gives the site real certainty in how they plan their turnarounds.”

James Turner,
Business Development Manager, IGS

One application. Seven years of verified performance. No rework required.

That’s Asset Vitality.